Description
The Multi Instruments gauge valve is a needle pattern valve with a non-rotating spindle tip, ensuring a positive bubble tight shut-off function.
Standard valves in stainless steel are suitable for most process applications, however for severe applications, needle valves in "exotic" materials are available.
Maximum working pressure is 420 Bar
Maximum temperature is 200°C
Connections
Vent and/or testports will always be 1/4" threadsize, independent of process connection sizes.
For ordering information please consult the Model Code Wizard for port connection types available.
Pressure vs. Temperature diagram
Design features
• Self aligning metal seats
• Compact Design
• Non-rotating spindle tip
• Metal seal between body and bonnet
• Bonnet Locking pins
• Safetyback seating T-Bar and Anti-Tamper operated valves
• Full traceability of all materials
• 100% pressure tested
Options
• Anti tamper facility with a removable T-bar key to prevent unauthorized operation of the valve
• Sour Gas Service
• Oxygen Service
• Available in Monel, Hastelloy, Duplex or NACE compliant materials.
• High temperature up to 450°C
• High pressure up to 680 Bar
Valve Diagram
Valve Drawing